EMERGENCY STOP XB5, SWITCHING OFF LATCHING TURN RELEASE 1NC RED

1 terjual dalam 17 jam terakhir
3 orang menambahkan produk ke keranjang
Merek: 
SCHNEIDER

red Ø40 Emergency stop, switching off pushbutton Ø22 latching turn release 1NC

Read more
  Estimasi Kirim: Sen, Jul 06  (Sabtu-Minggu Tutup)
  ... orang melihat produk ini sekarang

  Membagikan

Harga aslinya adalah: Rp226.495.Harga saat ini adalah: Rp124.572.

Tersedia

Specifications

Main
Range of productHarmony XB5
Product or component typeEmergency switching off push-button
Emergency stop push-button
Device short nameXB5
Bezel materialDark grey plastic
Fixing collar materialPlastic
Head typeStandard
Mounting diameter22.5 mm
Sale per indivisible quantity1
Shape of signaling unit headRound
Type of operatortrigger action and mechanical latching
ResetTurn to release
Operator profileRed mushroom Ø 40 mm, unmarked
Contacts type and composition1 NC
Contact operationSlow-break
Connections – terminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1
Device presentationComplete product
Complementary
Height43 mm
Width40 mm
Depth82 mm
Terminals description ISO n°1(11-12)NC
Resistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 m
Contacts usageStandard contacts
Positive openingWith conforming to IEC 60947-5-1 appendix K
Operating travel1.5 mm (NC changing electrical state)
4.3 mm (total travel)
Mechanical durability300000 cycles
Tightening torque0.8…1.2 N.m conforming to IEC 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to IEC 60947-5-4
Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to IEC 60947-5-4